ParkeParker Polyurethane Tubing: Understanding the 95U Series Nomenclature Updater

Parker Polyurethane Tubing Selection

Parker continues to refine and improve its product offerings to better serve customers, and the latest update to Parker Polyurethane Tubing is a great example. The recent nomenclature change for the 95U Series Polyurethane Tubing is designed to simplify product identification, improve consistency, and make ordering easier across the board.

If you currently specify, stock, or use Parker Polyurethane Tubing, understanding these updates will help ensure a smooth transition.

What Is Changing with Parker Polyurethane Tubing Nomenclature?

As part of a broader thermoplastic tubing update initiative, Parker has introduced a nomenclature change for its 95U Series Polyurethane Tubing. The goal is not to change the product itself, but to improve how it is identified, packaged, and referenced. This change is being implemented as a running update beginning April 15, 2026.

Key Nomenclature Updates

The updated naming structure for Parker Polyurethane Tubing includes several important enhancements:

  • Product series identification included in part numbers and descriptions
  • Metric tubing renamed from 95UM to 95U
  • Consistent 3-digit color coding (including NAT for natural)
  • Package quantity embedded directly into the part number

These changes make it easier to quickly identify tubing size, color, and packaging configuration directly from the part number.

Packaging Standardization

Another important update to Parker Polyurethane Tubing is the standardization of packaging.

  • Standard packaging options:
    • 100 ft retail packages
    • 500 ft reels
  • Select sizes may offer:
    • 1000 ft reels (upon request)

What This Means for Existing Part Numbers

Original Part NumberNew Part Number
95U-2-031-010095U-2-031-NAT-0100
95UM-4X.75-010095U-4×0.75-NAT-0100

Key differences

  • Addition of color code (e.g., NAT, BLK, BLU)
  • Inclusion of package length (e.g., 0100, 0500)
  • Standardized format across imperial and metric tubing

Metric tubing now aligns with the same naming convention as imperial sizes, eliminating the separate “95UM” designation.

Parker Polyurethane Tubing 95U Series Overview

While the nomenclature is changing, the core performance and features of Parker Polyurethane Tubing remain the same.

According to the Parker CAT4660 catalog (pages B-37 and B-38), the 95U Series offers:

Key Features

  • UV-resistant 95 Shore A durometer polyether-based resin
  • Excellent flexibility with rubber-like elongation and recovery
  • Chemical resistance typical of thermoplastics
  • Kink resistance for easier routing and installation

These characteristics make Parker Polyurethane Tubing ideal for applications requiring flexibility, durability, and reliable performance.

Operating Conditions

  • Temperature range: -40°F to 180°F (-40°C to 82°C)
  • Working pressure ratings based on 73°F (23°C)
  • Pressure decreases at elevated temperatures (refer to pressure vs. temperature charts)

Parker Polyurethane Tubing Specifications

Below are key specification tables adapted from the catalog (page B-38) for Parker Polyurethane Tubing.

Standard (Imperial) Sizes – 95U Series

Part NumberOD (in)OD (mm)ID (in)ID (mm)Wall (in)Working Pressure (psi)Burst Pressure (psi)Weight (lbs/ft)
95U-2-0311/83.20.0631.60.0312507500.005
95U-2.5-0315/324.00.0942.40.0311705100.006
95U-4-0451/46.40.1604.10.0451705100.015
95U-4-0621/46.40.1253.20.0622507500.019
95U-6-0623/89.50.2506.40.0621705100.030
95U-8-0621/212.70.3759.50.0621103300.042
95U-8-0901/212.70.3208.10.0901705100.059
95U-12-1253/419.10.50012.70.1251454350.125

Metric Sizes – 95U Series

Part NumberOD (mm)OD (in)ID (mm)ID (in)Wall (mm)Working Pressure (psi)Burst Pressure (psi)Weight (lbs/ft)
95U-4×0.7540.1572.50.0980.751905700.006
95U-6×1.0060.2364.00.1571.001705100.013
95U-8×1.5080.3155.00.1961.501905700.024
95U-10×1.75100.3936.50.2561.751705100.036
95U-12×2.00120.4728.00.3152.001504500.049

Why This Matters

The nomenclature update for Parker Polyurethane Tubing is ultimately about clarity and efficiency.

Benefits for Users:

  • Easier product identification
  • Reduced ordering errors
  • Consistent naming across product lines
  • Improved visibility of size, color, and packaging

For distributors and OEMs, these changes translate into simpler inventory management and smoother communication across teams.

Final Thoughts

The latest update to Parker Polyurethane Tubing—specifically the 95U Series nomenclature change—demonstrates Parker’s commitment to continuous improvement. While the tubing itself remains the same high-quality product, the enhanced naming structure makes it easier than ever to specify, order, and use.

If your team works with thermoplastic tubing, now is the time to familiarize yourself with the updated part numbers and packaging formats to ensure a seamless transition.

Contact our team with any questions or for help transitioning to the new part number nomenclature.